⚡ Solutions · Electrical & installation

Electrical & installation: 20 A, 30 mA, 36 W — four quantities, one shape

Three cut cable ends of increasing diameter on a dark background, the stranded copper core visible at each tip.

An electrician writes “DX3 20A curve C”, never “small breaker”. Rating, tripping curve and sensitivity all look alike — a number, a letter — and are never interchangeable.

Four quantities, one single shape

This is what makes the vertical hard for a general-purpose engine. A breaker carries a rating in amps, an RCD a sensitivity in milliamps, a luminaire a power in watts, a socket a voltage in volts. 20A, 30mA, 36W, 230V: four unrelated quantities, written the same way — a number glued to one or two letters.

A text search treats them as words and mixes them up. The electricite rule pack separates them, and with them the tripping curve and the RCD type — two lone letters an installation's compliance depends on (the detail of each attribute).

Rating, sensitivity and cross-section kept apart

The electricite rule pack activates when you pick your industry, at indexing time. It produces these annotations, each of which becomes a usable filter:

AnnotationWhat it isolates
CAL_20Athe rating of a modular device
SENS_30MAthe sensitivity of a residual-current device
COURBE_c · TYPE_acthe tripping curve and the RCD type
SECTION_2.5a conductor's cross-section, in mm²
CABLE_h07v-ua cable's harmonized designation
POLES_4the number of poles, in digits or spelled out
IP_40 · IK_07the protection ratings
PUISS_36W · TEMP_4000K · FLUX_3600a luminaire's power, colour temperature and output

To these are added the seven device families — breaker, RCD, cable, socket, switch, enclosure, luminaire — recognized in four languages, because a wholesaler orders from German and Italian manufacturers as readily as French ones. The second pass then brings together three couplings nobody searches for any other way: DISJ_20A, because a bare rating does not say whether it belongs to a breaker, a socket or a switch; DIFF_30MA, which separates the 30 mA of personal protection from the 300 mA of fire protection; and the cross-section tied to its cable, without which “2.5” floats between a length and a diameter.

Five references, exactly as a supplier writes them

Indexed referenceWhat the engine extracts
Disjoncteur DX3 20A courbe C 4500AFAM_DISJONCTEUR · CAL_20A · COURBE_c · DISJ_20A20 A breaker, curve C
Interrupteur differentiel 40A 30mA type ACFAM_DIFFERENTIEL · CAL_40A · SENS_30MA · TYPE_ac · DIFF_30MA40 A RCD, 30 mA, type AC
Disjoncteur tetrapolaire 32AFAM_DISJONCTEUR · CAL_32A · POLES_4 · DISJ_32Afour-pole breaker, 32 A
Cable H07V-U 2.5mm2 rouge couronne 100mFAM_CABLE · CABLE_h07v-u · SECTION_2.5 · CABLE_SECT_2.5H07V-U, 2.5 mm²
Dalle LED 36W 4000K 3600 lm IP40FAM_ECLAIRAGE · PUISS_36W · TEMP_4000K · FLUX_3600 · IP_4036 W, neutral white, 3,600 lumens, IP40

4,500 A is not a rating

On the first row of the table, two numbers followed by an A sit side by side: 20A is the rating, 4500A the breaking capacity. The first selects the product; the second is a characteristic nobody searches for.

The pack keeps only the first. This is the kind of distinction a text engine does not make: it would return this breaker on a search for “500A”, and the customer would conclude your catalog is badly organised.

The second pass then forms the buying pairs — DISJ_20A, DIFF_30MA, CABLE_SECT_2.5 — because a rating means nothing without the device carrying it: 20 A designates a breaker, a socket or a switch depending on what sits next to it.

What the pack does not recognize

Two trade spellings escape the rules, and it is better to know before indexing.

Cross-section written in ordering notation. A cable is ordered as 3G1.5 or 5G6 — number of conductors, then cross-section — and that form carries no unit. The pack requires “mm” to recognize a cross-section: 2.5mm2 is annotated, 3G1.5 is not. The cable stays findable by its designation and colour, but its cross-section does not become a filter unless the unit appears somewhere on the listing.

Halogen-free series. Harmonized designations with a digit in the middle — H05Z1-K and its family — are not covered. The common series are, including flexible conductors in -F.

In both cases a Custom Rule added from the console closes the gap on your catalog, with no regex to write.

The taxonomy already built for you

The electrical pack isolates the rating, the sensitivity and the protection rating as filterable attributes, not as text. You can then offer a “30 mA type A RCDs” or “IP65 luminaires” page without building the taxonomy yourself.

A manufacturer range the pack does not know, or a naming scheme of your own? Add your own Custom Rule from the console, describing what it should recognize.

Indexing your catalog

The getting started guide covers the full setup, from signup to your first indexed catalog. The documentation details every endpoint.

Watch the breakdown happen. The table above is the engine's output, not hand-written. The same mechanism runs on the home page, with no signup — on a hardware or fashion catalog, not electrical gear. What you see there is the annotation mechanism itself, the one the electricite pack applies to your ratings and IP indices.

Open the live engine →
14-day free trial

Test the Search API on your catalog, no credit card.

See pricing